TOC, TIC and TC Determination in Solids And Liquids In A Single Instrument
A new range of versatile catalytic combustion analysers from Analytic Jena are ideal for applications ranging from trace-level analysis of ultrapure waters to the analysis of drinking, ground and surface waters with medium TOC, or measuring highly contaminated, particulate waste waters.
Wembley, London, United Kingdom., December 7, 2011 - (PressReleasePoint) - The Multi N/C series of catalytic combustion analysers from Analytik Jena UK provide a versatile platform that can be configured for the fully automatic direct determination of bound carbon (TIC/TOC, TC, NPOC, POC) from liquid, paste or solid samples in a single instrument using the combustion analysis method. The Multi N/C series meets the requirements of DIN-EN, USEPA, ASTM, FDA and USP standards, including DIN EN 13137 for the determination of TOC in waste, sediments and sludge, and DIN EN 1484 and ISO 8245 for the detection of total and dissolved organic carbon in aqueous samples.
Instruments in the range include the Multi N/C 2100, Multi N/C 3100 and Multi N/C UV HS. The novel design provides an extended dynamic range for TOC measurements from 2 ppb up to 30000 ppm without dilution. This allows the systems to be used in applications ranging from trace-level analysis of ultrapure waters to the analysis of drinking, ground and surface waters with medium TOC, or measuring highly contaminated, particulate waste waters.
Direct measurement of solids is also possible with all the models in the range with the addition of the HT 1300 high-temperature solids combustion system. A click of the mouse is all that is required to change between solids and liquids mode.
This HT 1300 solids module provides catalyst-free high temperature combustion in a robust ceramic combustion tube using an additional furnace which is adjustable up to 1,300 °C.. Large solid samples of up to 3 g can be accommodated, which allows for solids with low homogeneity. The large dynamic measuring range of the N/C range is particularly suited for the detection of high TOC content (up to 500 mg C absolute) in solids.
High accuracy results are ensured using patented VITA® technology, which automatically determines the retention time of the sample in the analyzer. This not only leads to good accuracy and sensitivity but also excellent repeatability. VITA improves repeatability from typically 5-10% in the 0.5 – 1.0 mg/l range and 3-5% in the 1000 to 5000 mg/l range to 1-2% across the measuring ranges. In addition, VITA significantly reduces the intervals between calibrations to around 6 months, reducing running costs. Multi N/C series instruments can be calibrated across the entire detection range using a single standard sample, eliminating the need for a large number of standard reference materials.
The multi N/C® series can also be used for non-direct TOC determination of samples such as sediments, soil and lime stone using the so-called suspension method with no special accessories. This permits two different methods: TOC detection using the so-called direct method and the differential method. Another option for the detection of the TOC in specific matrices (e.g. sediments, soil, lime stone) is the suspension method. Different devices and technologies can be used to detect the parameter TOC in solid samples.
- end -
Enquiries: Vince Phelan, Analytik Jena UK, PO Box 932, Wembley, HA0 9EH, UK, Tel: +44 (0)208 429 7466, Fax: +44 (0)208 429 7539 E-mail: sales@aj-uk.co.uk http://www.analytikjenauk.co.uk
145ANJ
Wednesday, December 7, 2011
Press Contact:
Vince Phelan
Analytik Jena UK, PO Box 932, Wembley, HA0 9EH, UK
+44 (0)208 429 7466
http://www.analytikjenauk.co.uk
**l**@**-**.co.uk
Email partially hidden to block spam. Please use the contact form here.
More User Press Releases
- The World’s Best Tensioning Tools Will Be Shown in Russia for the First Time at Neftegaz 2012
- LCM Systems Increases Its Range of Stocked Load Cells for Faster Delivery to Customers
- New UK Business Manager Appointed at West Midlands Engineering Firm
- WAS - The Load Cells with the Hole in the Middle
- Automotive Centre of Excellence Selects Froude Hofmann
- ECITB Certified Bolt Training for Industry Now Available from the Experts
- Custom Designed Load Cell for Offshore Jacking System from LCM Systems
- For Customized Bolt Tensioning Tools, Speak to Tentec at Windpower 2012
- New Stocked Tension/Compression Load Cells from LCM Systems Means Lower Prices and Faster Delivery
- UK Engineering Company Wonders if These the World’s Largest Hydraulic Nuts
Like this site on Facebook
Distribute Press Release
- Post press release to 50+ free press release websites.
- Send to 100+ online publications.
- Effortlessly publish all your press releases with our automated pickup and submission service.
User login
Search
Bookmark/Search this post
Primary Menu
- News by Region
- Business
- List of Industries
- Technology
- Aerospace & Defense
- Agriculture & Forestry
- Arts
- Automotive
- Business Services
- Chemicals
- Construction & Maintenance
- Consumer Goods
- Education
- Electrical & Electronics
- Energy
- Entertainment
- Food & Related Products
- General Business
- Government
- Healthcare
- Heavy Industry
- Home
- Industrial Goods & Services
- Industrial Materials
- Medical
- Mining & Drilling
- Publishing & Printing
- Retail
- Society
- Sports
- Supermarkets
- Telecommunications
- Textiles & Nonwovens
- Transportation & Logistics
- Travel & Hospitality
- Wholesale